Wooden Fire Doors

60 Min(1Hours) - Fire Doors

SUN DOORS & SYSTEMS make 1 Hour fire rated doors system duly tested for integrity & Insulation as per the IS:3614 part 2 and BS:476 part 20 at FRL CBRI Roorkee with standard heating conditions as specified in IS:3809 - 1979 and BS:476 part 20 & 22 1987 to achieve the required integrity & insulation.

Providing, Supply & Fixing of ARDOR-PROMAT make 1Hours fire rated doors system duly tested for integrity & Insulation as per the IS:3614 part 2 and BS:476 part 20 at FRL CBRI Roorkee with standard heating conditions as specified in IS:3809 -1979 and BS:476 part 20 & 22 1987 to achieve the required integrity & insulation (I.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140 degree Celsius above the ambient temperature on the unexposed surface of the shutter), Unfinished hardwood frame of section 100mm X 50mm ( Finished Section of 90mm X 43mm) with 2nos. of Promaseal Intumescent strip to take care of Hot smoke size of 10mm X 2mm canceled in the grove of the frame with fixing arrangements of 3 nos. of G.I. hold fast 225mm X 20mm X 4mm with split end on ether side and wall grouted with cement concrete mix 1:3:6 adjustable lugs with split end tail to each jamb, including 4 nos. of stainless steel ball bearing hinges of SS 304 quality of size 76mm X 102mm X 3mm thick to capable of taking load up to 120 Kg of the shutter with SS pin, lock strike plate, shock absorbersas specified and 45mm thick single leaf shutter made out of 2 Nos of 18mm thick Marine Ply sandwichedwith 9mm thick Promatect-50 board with Promaseal Fire Intumescent Seal of size 20mm x 2mm mounted in the grooves in the shutter onall sides except bottom with 15mm thick teak wood beading on all side and Promaseal Intumescent sealant is used to seal the gaps between Promatect-50 board Board and shutter beading. The fire Doors with frame will be tested as per BS:476 part 20 at FRL Fire Reserch Lab at Malaysia with standard heating conditions as specified in BS:476 part 20 & 22 1987 all complete to the entire specification with the certified copy of the valid Test Certificates to be issued by M/s.ARDOR & Promat International Asia Pacific Ltd.

120 Min(2Hours) - Fire Doors

SUN DOORS & SYSTEMS make 2 Hours fire rated doors system duly tested for integrity & Insulation as per the IS:3614 part 2 and BS:476 part 22 at FRL CBRI Roorkee with standard heating conditions as specified in IS:3809 - 1979 and BS:476 part 20 & 22 1987 to achieve the required integrity & insulation (i.e. to confine the fire/smoke and to restrict the temperature rise on the non fire side below 180°C at any given time during the fire condition")

Providing, Supply & Fixing of PROMAT make 2 Hours fire rated doors system duly tested for integrity & Insulation as per the IS:3614 part 2 and BS:476 part 20 at FRL CBRI Roorkee with standard heating conditions as specified in IS:3809 -1979 and BS:476 part 20 & 22 1987 to achieve the required integrity & insulation (I.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140 degree Celsius above the ambient temperature on the unexposed surface of the shutter), Unfinished hardwood frame of section 150mm X 75mm ( Finished Section of 143mm X 63mm) with 2nos. of Promaseal Intumescent strip to take care of Hot smoke size of 10mm X 2mm canceled in the grove of the frame with fixing arrangements of 3 nos. of G.I. hold fast 225mm X 20mm X 4mm with split end on ether side and wall grouted with cement concrete mix 1:3;6 adjustable lugs with split end tail to each jamb, including 4 nos. of stainless steel ball bearing hinges of SS 304 quality of size 76mm X 102mm X 3mm thick to capable of taking load up to 120 Kg of the shutter with SS pin, lock strike plate, shock absorbers as specifiedand 56mm thick single leaf shutter made out of perimeter railing of RedMarenti hard wood of size 100mm X 30mm and 2 nos. of 9mm thick Promina –60 board with 30mm thick Non–combustible Fire Retardant compound and faced with 3mm thick Plywith Promaseal Fire Intumescent Seal of size 20mm x 2mm mounted in the grooves in the shutter on all sides except bottom with 10mm thick teak wood beading on all side and Promaseal Intumescent sealant is used to seal the gaps between Promina-60 Board and shutter beading. The fire Doors with frame will be as per IS:3614 part 4 and BS:476 part 20 at FRL CBRI Roorkee with standard heating conditions as specified in IS:3809 -1979 and BS:476 part 20 & 22 1987 all complete to the entire specification with the certified copy of the valid Test Certificates to be issued by M/s.Promat International Asia Pacific Ltd.

Wooden Flush Doors

A flush door has a basic structure composed of solid blockboard core, vertical stiles, and horizontal rails that create a pre-fixed frame. The blockboard is composed of wooden strips that are placed edge-to-edge and sandwiched between veneers, then bonded under high pressure and temperature using a synthetic resin. So in a simpler term, it is a door that is made of a timber frame covered with ply from both the sides and then the hollow part inside is filled with rectangular blocks of soft wood. Then a decorative finish is given by fixing veneer on the top. A flush door is so called because it has an entirely smooth surface. If water were to be splashed on its surface, it would simply flow off its surface without accumulating.

We can Customized Door as per Clients requirement:

  • Door 300mm Pine Door M/R Quality
  • 35mm Pine Door M/R (WP) Quality
  • We can Paste both side laminate Decoration